Cape-11R Rope RF Admittance Level Switch
  • Cape-11R Rope RF Admittance Level Switch
  • Cape-11R Rope RF Admittance Level Switch
  • Cape-11R Rope RF Admittance Level Switch
  • Cape-11R Rope RF Admittance Level Switch

Cape-11R Rope RF Admittance Level Switch is specially designed for top-mounting applications in which the probe length is longer than 2 meters. A cable component is connected to extend the probe end. Cape-11R is suitable for larger tanks and silos, the vertically installation can effectively avoid material impaction.

In Cape-11 RF series, a probe is designed to detect the change of capacitance and impedance between probe and vessel wall to realize level measurement and control. In its electronic unit, reactance between the measurement electrode and the wall of an empty vessel constitutes a balanced bridge circuit which outputs a stable oscillation signal. As the level rises, the measurement electrode is covered by the medium, and reactance between the electrode and the wall of the vessel changes. It causes an imbalance of the bridge circuit and stops the oscillation as a result. A post-circuit is designed to detect the change of output signal from the bridge circuit and generate an alarm signal. In addition, oscillation signal at radio frequency is not only applied to the measurement electrode but also applied to a shield pole through a 1: 1 voltage-follower, so measurement electrode and shield pole have the same electric potential, phase, and frequency, but these two electrodes are insulated from each other. Even if there is medium buildup on the probe, because there is no electric potential difference between measurement electrode and shield pole, the reactance change on shield pole has no effect on the detection of post-circuit. Therefore, only reactance change on the measurement electrode induced by the filled medium between the measurement electrode and the wall of the vessel will be detected by post-circuit. It eliminates the effect of medium buildup on level measurement.

● For level control in large containers and silos.

● With an external dual color LED indicator. Housing with electronic can be rotated to make the orientation of LED indicator convenient for long distance observation.

● Modular design for high reliability, easy installation and maintenance.

● Passed third party reliability tests and received certifications from the third party, guaranteed extremely high reliability.

Applicable mediumTypes of the mediumCoal ash, fly ash, dust
Dielectric constant≥1.6
Probe dataProbe length600~6000mm
Shield length90~800mm, depends on probe length and customer´s requirement
Cable diameterφ6mm
MaterialsHousingAluminum alloy
Inner housingPlastic
Probe metallic parts304, 316L
Probe insulation partsPTFE
Cable304
Power SupplyAC85~264V AC
DC18~30V DC
Power consumption≤3W
Switching DelayWhen immersed1s
When laid bare1s
OutputRelayDPDT,8A/250V AC/30V DC
Relay delay0~30s Continuous adjustable
Installation conditionsProcess temperature-40~250℃
Ambient temperature-40~70℃
Storage and transport temperature-40~80℃
Certificates and approvalsIngress ProtectionIP66

● Long measuring range for large coal bunkers at coal-fired power plants.

● Long measuring range for large cement silos or bunkers at cement plants.

Cape-11R Rope RF Admittance Level Switch