Tube-11 Ultra High-Temperature Vibrating Rod Level Switch
  • Tube-11 Ultra High-Temperature Vibrating Rod Level Switch
  • Tube-11 Ultra High-Temperature Vibrating Rod Level Switch

Tube-11 Ultra High-Temperature Vibrating Rod Level Switch is featured with the function of water cooling (air cooling) and is able to work reliably under ultra-high temperature conditions that up to 400℃ (482°F).

The operating principle is completely the same as that of the standard Tube-11 model. In terms of the structure, high-temperature model is assembled an extension tube between the housing and the process connection, so that the temperature in the housing can be reduced to a normal range where the electronic devices can tolerant. At the same time, all piezoelectric components that drive and detect the vibration are selected from high-temperature resistant piezoelectric ceramics, electrodes, wires, and encapsulant materials. These high-temperature designs ensure the instrument work reliably in process temperature conditions up to 400 ℃.

● High temperature resistant design with double vibration elements, process temperature up to 400 ℃ (482°F).

● The innovative developed technology enables the sensor to detect fine-grained solids with density as low as 0.02 g/cm³.

● Excellent in the precipitates interface measurement of liquids.

● An industry leading product that can tolerate high process temperature up to 400℃ (Water/air cooling).

● Strong self-diagnostic function helps to accurately locate the fault.

● Simple installation and maintenance free.

● With CE certificates, gas/dust Flameproof Enclosure and gas/dust Intrinsic Safety certificates, and IP66/IP67 Ingress Protection.

● Made of strong corrosion resistant material 316L.

Applicable mediumTypes of the mediumGranular or powdery solids ①
Density≥0.02g/cm³
Probe dataVibration frequency~ 360Hz
Probe length125mm
Probe diameter16mm
Switching DelayWhen immersed0.5s
When laid bare1s
Power SupplyRelay20~253V AC/20~72V DC
Two-wire10~36V DC
Max. Power consumption8VA(AC); 1.5W(DC)
OutputRelayDPDT,5A/253V AC/24V DC
Two-wire8mA/16mA,Alarm <2.3mA
Installation conditionsProcess pressure-1~16bar
Process temperatureRegular temperature: -50~150℃
High temperature: -50~250℃ Ultra-high temperature: -50~400℃
Ambient temperature-40~80℃
Storage and transport temperature-40~80℃
Cooling system data (for Ultra-high temperature only)Air intake tube6×4  (Outer diameter 6mm) PU tube
Cooling air pressure0.8Mpa
Min. cooling air flow rateTo be adjusted②
Overvoltage protectionRelayCategory III, class I
Two-wireCategory III, class II
Certificates and approvalsIngress ProtectionIP66/IP67
Explosion-ProofFlameproof Enclosure::Ex d IIC T6~T1 Gb, Ex tD A21 IP66 T80~440℃ Intrinsic Safety:Ex ia IIC T6~T1 Ga, Ex iaD 20 T85~450℃
CELVD and EMC Certificates
MaterialsHousingAluminum alloy, stainless steel
Ground terminal316L
Process connection316L
Probe316L, 318 S13
Process sealKlingersil C-4400

Note: ① Maximum applicable particle size is 20mm, in this case, medium density must be lower than 0.05g/cm³.
② Cover exhaust nozzle with whistle from instrument accessories and position the whistle such that whistle’s internal wall at its vent side is tightly attached to the external wall of exhaust nozzle, slowly increase the flow of cooling air until whistle blows up. This is when cooling air is at the expected minimum flow.

● Level measurement of fine-grained solids with density as low as 0.02 g/cm³ in the process temperature up to 400 ℃ (482°F).

● Precipitates interface measurement of liquids in the process temperature up to 400 ℃ (482°F).

Tube-11 Ultra High-Temperature Vibrating Rod Level Switch